CHANGING HYDRAULIC FLUID
1. Make sure power switch (FIG. 13-1) is
turned on. Then, lower platform to the
ground (FIG. 13-1).
POWER SWITCH
LIFT AT GROUND LEVEL
(RH SIDE SHOWN)
FIG. 13-1
UNBOLTING PUMP COVER
(LH PUMP SHOWN)
FIG. 13-2
SCREWS
PUMP COVER
2. Unbolt the pump cover as shown
in FIG. 13-2.
MEASURING HYDRAULIC FLUID LEVEL
(LH PUMP SHOWN)
FIG. 13-3
RESERVOIR
“L”
3. Measure hydraulic uid level “L” in
reservoir (FIG. 13-3).