11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
10
PATENTS PENDING
NOTE: The Lift controller counts the number of cycles & lifts over the lifetime of the Lift.
One CYCLE is counted each time the Lift is unfolded from the stowed position to
oor level, lowered to the ground, raised to oor level, and then stowed. One LIFT
is counted each time the Lift is lowered from oor level to the ground, and raised
back to oor level. Read the LIFTS and CYCLES counts from the Lift control-
ler display window periodically so you know when to do the maintenance checks
listed below.
MAINTENANCE SCHEDULE
EVERY 500 LIFTS
NOTE: To con rm compliance with Federal Motor Vehicle Safety Standard 403, refer to
the COMPLETED LIFT INSTALLATION CHECKLIST in the Installation Manual.
Check that all decals are in place, undamaged, and legible (see PARTS BREAK-
DOWN, DECALS).
Visually check the Lift for bent, broken, or worn out parts, and broken welds.
Check the electrical wiring for worn insulation, and the terminals for corrosion
and secure t. Apply dielectric grease to connections if needed.
Visually inspect the latch solenoids. If necessary, replace both latch solenoids P/N
266955-01 (see PARTS BREAKDOWN, ELECTRICAL COMPONENTS, Item 19).
Check for loose fasteners (nuts, bolts, screws & rivets). Also, check cotter pins, clevis
pins, retaining ring pins & retaining rings for noticeable wear and damage.
Check that all anti-slip and safety striping is in place and undamaged (see PARTS
BREAKDOWN, ANTI-SLIP & SAFETY STRIPING).
EVERY 2500 CYCLES
Apply multi-use te on spray lubricant to the inboard rollstop spring lock & the plunger
switch spring on the Lift.
EVERY 5000 LIFTS
Replace both platform light bulbs P/N 906475-01 (see PARTS BREAKDOWN, ELEC-
TRICAL COMPONENTS, Items 26A & 27A).
Check both hydraulic cylinders for leaks. If a lm of hydraulic uid is visible on cylinder
seals, Lift can still be operated. However, if uid is dripping from the cylinders, replace
them (see PARTS BREAKDOWN, HYDRAULIC COMPONENTS, Item 8).