Maxon WL7-vers. C Especificações Página 20

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 19
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
20
PATENTS PENDING
8. Put 25-pound weight
on threshold plate (FIG.
20-1). The warning alarm
and beacon lights should
turn on. If alarm and bea-
con lights don’t come on,
alternately turn left side
and right side adjustment
screws clockwise until
alarm & beacon lights are
turned on.
25 POUND WEIGHT ON THRESHOLD PLATE
FIG. 20-1
9. Move 25-pound weight to
several different places
across threshold plate
(FIG. 20-1). Alarm and
beacon lights should turn
on with load anywhere on
threshold plate.
THRESHOLD (MAT) SWITCH ADJUSTMENT - Continued
Vista de página 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 106 107

Comentários a estes Manuais

Sem comentários