11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
10
PATENTS PENDING
NOTE: The Lift Controller counts the number of cycles & lifts over the lifetime of the Lift. One
CYCLE is counted each time the Lift is unfolded from the stowed position to floor
level, lowered to the ground, raised to floor level, and then stowed. One LIFT is
counted each time the Lift is lowered from floor level to the ground, and raised back to
floor level. Read the LIFTS and CYCLES counts from the Lift Controller display
window periodically so you know when to do the maintenance checks listed below.
MAINTENANCE SCHEDULE
EVERY 500 LIFTS
NOTE: To confirm compliance with Federal Motor Vehicle Safety Standard 403, refer to
the COMPLETED LIFT INSTALLATION CHECKLIST in the Installation Manual
MP-04-01.
Check that all Decals are in place, undamaged, and legible (see DECALS pages).
Visually check the Lift for bent, broken, or worn out parts, and broken welds.
Check the electrical wiring for worn insulation, and the terminals for corrosion
and secure fit. Apply dielectric grease to connections if needed.
Replace both latch Solenoids P/N 266955-01 (see ELECTRICAL COMPONENTS,
Item 23).
Check for loose fasteners (nuts, bolts, screws & rivets). Also, check cotter pins, clevis
pins, retaining ring pins & retaining rings for noticeable wear and damage.
Check that all anti-slip and safety striping is in place and undamaged (see ANTI-SLIP &
SAFETY STRIPING pages).
EVERY 2500 CYCLES
Check the Inboard Rollstop Actuator Assembly wiring connections, routing, and condition
from Actuator to Controller. Repair if needed (see PLATFORM CLOSER, Item 4 &
ELECTRICAL SYSTEM DIAGRAM).
EVERY 3000 LIFTS
Check the large bearing on slider-end of Actuator. If bearing looks worn at first inspection,
remove and reinstall bearing with the ends reversed. Replace bearing P/N 266545-03
(see PLATFORM CLOSER, Item 14), if follow-on inspections reveal more wear.
EVERY 5000 LIFTS
Replace both Platform light bulbs P/N 906475-01 (see ELECTRICAL COMPONENTS,
Item 8A).
Check both Hydraulic Cylinders for leaks. If a film of hydraulic fluid is visible on cylinder
seals Lift can still be operated. However, if fluid is dripping from the cylinders, replace
them (see HYDRAULIC COMPONENTS, Item 13).
EVERY 10000 LIFTS