PATENTS PENDING
RH SIDE OF LIFT
FIG. 15-1A
ADJUSTING SWITCH
FIG. 15-1B
BASE
PLATE
THRESHHOLD
PLATE
ADJUSTMENT
SCREW
THRESHOLD
WARNING BEACON
4. Turn the MAT switch adjustment
screw (FIG. 15-1B) clockwise
(FIG. 15-2) until Threshold Warn-
ing Alarm and Beacons are acti-
vated (FIG. 15-1A). Then turn
adjustment screw counter-clock-
wise (FIG. 15-2) approximately 1
turn. Warning Alarm and Beacons
should turn off.
5. Step on Threshhold Plate. Warning
Alarm and Beacons should activate.
If the Warning Alarm and Beacons
do not activate, turn Adjustment
Screw (FIG. 15-1B) clockwise (FIG.
15-2) a little. Repeat until Warning
Alarm and Beacons activate when
you step on Threshhold Plate and
turn off when you step off Threshhold
Plate.
MAT SWITCH ADJUSTMENT SCREWS
FIG. 15-2
1 TURN CCW-
ALARM & BEACONS
TURN OFF
CW -
UNTIL ALARM &
BEACONS TURN ON