11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
7. Turn the adjustment
screw clockwise
on right side of
threshold plate (FIG.
63-1B), until thresh-
old warning alarm
and beacon lights
are turned on (FIG.
63-1A). Next, turn
adjustment screws
counter-clockwise
until threshold warn-
ing alarm and bea-
con lights are turned
off. Then, turn ad-
justment screw ap-
proximately 1/4-turn
counter-clockwise
(FIG. 63-2).
RH SIDE OF LIFT
FIG. 63-1A
ADJUSTING SWITCH
FIG. 63-1B
THRESHOLD
PLATE
THRESHOLD
WARNING
BEACON
THRESHOLD SWITCH ADJUSTMENT SCREWS
FIG. 63-2
CW - UNTIL ALARM &
BEACONS TURN ON
1/4-TURN CCW - ALARM &
BEACONS TURN OFF
ADJUSTMENT
SCREW
THRESHOLD
WARNING
ALARM