Maxon WL7-vers. C Manual do Operador Página 64

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 74
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 63
PATENTS PENDING
64
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
8. Put 25-pound weight
on threshold plate (FIG.
64-1). The warning alarm
and beacon lights should
turn on. If alarm and bea-
con lights don’t come on,
alternately turn left side
and right side adjustment
screws clockwise until
alarm & beacon lights are
turned on.
25 POUND WEIGHT ON THRESHOLD PLATE
FIG. 64-1
9. Move 25-pound weight to
several different places
across threshold plate
(FIG. 64-1). Alarm and
beacon lights should turn
on with load anywhere on
threshold plate.
THRESHOLD (MAT) SWITCH ADJUSTMENT - Continued
Vista de página 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 73 74

Comentários a estes Manuais

Sem comentários